A must have utility for electrician's, electrical contractors or those looking to pass an electrical certification.
Calculations per National Electric Code 2014.
Calculations included:
Voltage Drop
-Circuit’s Conductors voltage drop.
-Minimum Conductor Size.
Pipe Bend
-Offset.
-Three bend saddles.
-Rolling Offset
-Detail Conduit Support.
-Segment bending.
Raceway calculations.
-Raceway size calculation.
-Raceway calculation
-Maximum number of same size wires
-Conduit Support\n-Conductors Support
-Conduit spacing
-Conductor Applications and Insulations
-Cable Tray Calculation
-Metric Trade Size Designators.
-R90, RW75, TWN75,T90, TW, TW75, TWU, TWU75
Ampacity
-Conductor Ampacity, wire size.
-table 301.15(B)(16).
Box Fill
-Sizing outlet box.
-Sizing Pull box.
Load calculation (Residential)
-Single family.
-Range and dryer’s calculation.
-Service \ Feeder Conductors.
Transformers
-Transformers Size.
-Transformers OCPD calculations.
-Transformers Short Circuit calculations.
-Delta-Wye transformers Calculations.
Motors calculations
-Motor OCPD calculations.
-Motor NEMA Starters calculation.
-Motor Locked Rotor Calculation.
Electrical schematics
- Delta-delta transformers.
- Delta-Wye transformers.
- Three way switch.
- Start/stop AC motor.
- 3 phase A.C. Motor Winding and Connections Wye
- 3 phase A.C. Motor Winding and Connections Delta
- Network cable wiring pin-out.
- Wye Start-Delta Run.
- Electrical Symbols
Burial Depth
-600v or less.
-Over 600v.
Grounding
-Equipment Grounding
-Grounding Electrode Conductor.
-Grounded Conductor, Main Bonding Jumper, System Bonding Jumper, and Supply-Side Bonding Jumper for Alternating-Current Systems.
NEMA Device Configurations.
-Plugs.
-Enclosures.
Electrical Calculations.
-Formula Wheel.
-Power Triangle.
-Series/Parallel.
NEC Tables section.
Color Code.
-Resistors color code.
-Phase wire color code.
-Panel color code.
NEC Calculations Examples.
-Bank load calculation.
-Store load calculation.
-Scholl load calculation.
-Multi-family dwelling load calculation.
-Office building load calculation.
-Restaurant load calculation.
-Motor I load calculation.
-Motor II load calculation.
-Ranges load calculation.
2014 NEC Code Changes.
Units Converter.
- Temperature.
- Energy.
- Length.
- AWG to millimeter.
- Watts to Lumens.
- Torque.
NFPA 70E Table 130.7 (C) (16).
Arc Flash Calculation.
- NFPA 70E Table 130.7 (C) (15)(a).
Torque Specs for lugs and bolts.
- Squared D.
- GE.
-more coming soon.
release version history:
(1.2.6.15) Dec 14, 2015
(1.2.4.2.5) Feb 5, 2013
National Electrical Code and "NEC" are registered trademarks of the NFPA
-And more coming soon! Stay tuned for updates.
If you like to report bugs or suggestions, please send them to <a href="mailto:electricianbible@gmail.com">electricianbible@gmail.com</a>
</div> <div jsname="WJz9Hc" style="display:none">A doit avoir l'utilité pour les électriciens, les entrepreneurs du électriques ou ceux qui cherchent à passer une certification électrique.
Calculs par National Electric Code 2014.
Calculs inclus:
Chute de tension
Conducteurs de la chute de tension de -Circuit.
-Minimum Taille du conducteur.
Tuyau Bend
-Offset.
Selles bend -Trois.
-Rolling Offset
-Detail Conduit Support.
Flexion -Segment.
Calculs Raceway.
Calcul de la taille -Raceway.
Calcul -Raceway
Numéro -Maximum des mêmes fils de taille
-Conduit Support \ n-conducteurs Soutien
Espacement -Conduit
Applications -Conductor et isolations
-TV Câble Plateau Calcul
-metric Codes de dimension commerciale.
-R90, RW75, TWN75, T90, TW, TW75, STT, TWU75
Ampacity
-Conductor Ampacity, la taille du fil.
-table 301.15 (B) (16).
Box Fill
Boîte de sortie -Sizing.
-Sizing Boîte de tirage.
Calcul de la charge (Résidentiel)
-Famille mono-parentale.
-Gamme Et le calcul de la sécheuse.
-Service \ Feeder conducteurs.
Transformateurs
-Transformers Taille.
Calculs -Transformers OCPD.
-Transformers Calculs de court-circuit.
-Delta-Wye transformateurs calculs.
Moteurs calculs
Calculs -Motor OCPD.
Calcul -Motor NEMA Entrées.
-Motor Rotor bloqué calcul.
Schémas électriques
- Transformateurs Delta-Delta.
- Transformateurs Delta-Wye.
- Commutateur à trois voies.
- Start / Stop moteur à courant alternatif.
- 3 phases de courant alternatif bobinage moteur et connexions Wye
- 3 phases AC Motor liquidations et Connexions Delta
- Câblage de réseau pin-out.
- Démarrer Wye-Delta Exécuter.
- Symboles électriques
La profondeur d'enfouissement
-600v Ou moins.
-Plus De 600v.
Mise à la terre
Grounding -Equipément
-Grounding Conducteur d'électrode.
-Grounded Conducteur, principal Bonding Jumper, système de collage Jumper, et Supply-Side Bonding Cavalier pour courant alternatif Systems.
NEMA Configurations de l'appareil.
-Plugs.
Encoffrements.
Calculs électriques.
Roue -Formule.
-Alimentation Triangle.
-Series / Parallèle.
Section des tableaux NEC.
Code couleur.
-Resistors Code de couleur.
-Phase Fil code de couleur.
Code couleur -Panel.
NEC Calculs exemples.
Calcul de la charge -Bank.
Calcul de la charge -Store.
Calcul de la charge -Scholl.
Calcul de la charge d'habitation -Multi-famille.
Calcul de la charge de la construction -Office.
Calcul de la charge -Restaurant.
-Motor Je charge le calcul.
Calcul -Motor II de charge.
Calcul de la charge -Ranges.
2014 Modifications du code NEC.
Units Converter.
- Température.
- Énergie.
- Longueur.
- AWG à millimètre.
- Watts Lumens.
- Couple.
Tableau NFPA 70E 130,7 (C) (16).
Calcul Arc flash.
- NFPA 70E Tableau 130,7 (C) (15) (a).
Spécifications de couple pour cosses et boulons.
- Squared D.
- GE.
-plus à venir bientôt.
libérer l'histoire de version:
(1.2.6.15) 14 décembre 2015
(1.2.4.2.5) 5 février 2013
National Electrical Code et «NEC» sont des marques déposées de la NFPA
-Et À venir bientôt! Restez à l'écoute pour les mises à jour.
Si vous souhaitez signaler des bugs ou suggestions, s'il vous plaît envoyez-les à <a href="mailto:electricianbible@gmail.com">electricianbible@gmail.com</a></div> <div class="show-more-end">